DB2 - Problembeschreibung
Problem IT10012 | Status: Geschlossen |
SQLCODE -302 IS RETURNED DURING STATIC SQL EXECUTION INSTEAD OF BIND/REBIND | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / A50 - DB2 | |
Problembeschreibung: | |
Binding or rebinding a static application should detect invalid host variable information (such as a DECIMAL with precision 0) and return SQLCODE -302. In some circumstances, the invalid host variable information may not be detected at bind/rebind, and is recorded in the section. This results in SQLCODE -302 at execution time instead. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 version 10.5 fix pack 7 * **************************************************************** | |
Local-Fix: | |
Ensure host variable information is valid | |
Lösung | |
First fixed in DB2 version 10.5 fix pack 7 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 10.07.2015 20.01.2016 20.01.2016 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
10.5.0.7 |