Informix - Problem description
Problem IC60274 | Status: Closed |
ERROR CANNOT CREATE SMX PIPES WHEN TRYING TO START HDR | |
product: | |
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50 | |
Problem description: | |
You have enabled Server Multiplexer Group (SMX) connections on the database server. You run onmode -d secondary <primary>. The secondary connects to the primary but you see an error message like this in the secondary server's message log: 14:11:42 DR: new type = secondary, primary server name = abc 14:11:42 DR: Trying to connect to primary server = abc 14:11:42 DR: Cannot connect to primary server 14:11:42 DR: Turned off on secondary server 14:11:42 Cannot create SMX pipes 14:11:44 DR: Secondary server connected | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * HDR users * **************************************************************** * PROBLEM DESCRIPTION: * * The database server does not verify the primary name in the * * onmode -d secondary <primary> command and this causes * * problems for SMX connections but not other types. * **************************************************************** * RECOMMENDATION: * * Please upgrade to IDS 11.50.xC5 or above. * **************************************************************** | |
Local Fix: | |
Make sure the primary servername in your onmode -d command is correct. | |
Solution | |
Problem has been fixed in IDS 11.50.xC5. | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 05.03.2009 27.07.2009 27.07.2009 |
Problem solved at the following versions (IBM BugInfos) | |
11.50.xC5 | |
Problem solved according to the fixlist(s) of the following version(s) | |
11.50.xC4.W1 | |
11.50.xC5 |