Informix - Problem description

Problem IC60307 Status: Closed

CONNECTION MANAGER SHOULD PROVIDE FAILOVER MANAGEMENT WHEN A FAI LED
PRIMARY IS BEING RESTARTED

product:
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50
Problem description:
Using HDR (without connection manager) it is possible to control 
behavior after a failed primary is being restarted. 
This is   done by setting DRAUTO to 1 or 2. 
The same functionality should exist when a connection manager is 
being used (and therefore DRAUTO = 3). 
It should be possible to control if a previously failed primary 
will become primary again, or become secondary instead. 
Currently restarting the primary just fails with 'paired server 
is in incompatible mode' if DRAUTO is set to 1, and a connection 
manager is running, 
Restarting the failed primary will lead to the primary hanging 
in fast recovery, and the secondary hanging in shutdown 
mode - due to to existing connection manager connection. 
The switch back to the original configuration will only complete 
after connection manager is shut down. 
This behavior is independent of the foc setting used in the 
connection manager configuration.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* 11.50 users with HDR and connection manager                  * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* When running HDR with DRAUTO=1, and connection manager with  * 
* FOC=DISABLED, bouncing the primary server will leave the     * 
* primary in fast recovery mode and will leave the HDR         * 
* secondary in shutdown mode.                                  * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to IDS 11.50xC5 or later.                            * 
****************************************************************
Local Fix:
Solution
Problem first fixed in IDS 11.50xC5.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.03.2009
23.07.2009
23.07.2009
Problem solved at the following versions (IBM BugInfos)
11.50.xC5
Problem solved according to the fixlist(s) of the following version(s)
11.50.xC4.W1 FixList
11.50.xC5 FixList