Informix - Problem description

Problem IC61754 Status: Closed

CONNECTION MANAGER FAILS TO REGISTER ON PRIMARY DATABASE SERVER WHEN USING
MULTIPLE CONNECTION MANAGERS

product:
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50
Problem description:
With multiple connection managers running in a cluster, if the 
primary node is bounced and failover does not occur, then the 
active failover arbitrator within that connection manager can 
detect when the original primary is active again. However, the 
inactive failover arbitrators running on the remaining 
connection managers are not able to detect when the original 
primary is active. 
. 
The cm log continue to display the following error message: 
Arbitrator = xxx_cm not active, waiting to detect primary 
[cmsm_arb.c:938]
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Users using the connection manager oncmsm.                   * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* With multiple connection managers running in a cluster, if   * 
* the primary node is bounced and failover does not occur,     * 
* then the active failover arbitrator within that connection   * 
* manager can detect when the original primary is active       * 
* again. The inactive failover arbitrators running on the      * 
* remaining connection managers are not able to detect when    * 
* the original primary is active.                              * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Please upgrade to ClientSDK 3.50.xC6 and above.              * 
****************************************************************
Local Fix:
Bounce the connection manager.
Solution
Problem fixed in ClientSDK 3.50xC5.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
26.06.2009
22.01.2010
22.01.2010
Problem solved at the following versions (IBM BugInfos)
3.50.xC5,
3.50.xC6
Problem solved according to the fixlist(s) of the following version(s)
11.50.xC5 FixList