DB2 - Problem description
Problem IC61875 | Status: Closed |
INSTANCE ABEND WHEN USING STATEMENT EVENT MONITOR AND INCORRECT PACKAGE SIZE LENGTH IS CONTAINED IN THE DRDA MESSAGE. | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
When a statement event monitor is active and an incoming request to execute a statement contains an invalid package name length, it is possible that the instance will abend. A typical trap file may show function agent_stmt_start at the top. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * Instance abend is possible in monitoring code. * **************************************************************** * RECOMMENDATION: * * Upgrade to v9.7 fixpak 1 ( server side ) * **************************************************************** | |
Local Fix: | |
n/a | |
available fix packs: | |
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows | |
Solution | |
Problem was first fixed in Version 9.7 Fix Pack 1 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 07.07.2009 18.12.2009 18.12.2009 |
Problem solved at the following versions (IBM BugInfos) | |
9.7., 9.7.FP1 | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.1 |