DB2 - Problem description

Problem IC64518 Status: Closed

A QUERY EXECUTED AGAINST 2 OR MORE OLEDB TABLE FUNCTIONS THAT REFERENCES
THE SAME DATA SOURCE RETURNS SQL1182 ERROR.

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
If a select query is executed against 2 or more OLEDB table 
functions that references the same data source, SQL1182 error is 
returned. 
 
Eg) 
 
1) View V1 was created with a reference to a table function F1. 
 
 
CREATE VIEW V1 AS SELECT * FROM TABLE(F1( )) OLEDBTB; 
 
Where the table function F1( ) uses Provider=SQLOLED and gets 
data from SQL server. 
 
 
2) View V2 was created with a reference to a table function 
 
CREATE VIEW V2 AS SELECT * FROM TABLE(F2( )) OLEDBTB; 
 
Where the table function F2 also gets the data from the same SQl 
Server data source. 
 
 
 
3) View VW is a join of the V1 and V2 views noted above. 
 
 
Queries ran directly against views V1 & V2 are successful. 
 
A query ran against view VW fails with the error 
 
Select from V1 works 
 
Select from V2 works 
 
Select from VW throws this error; 
      0 rows selected because of ERROR. 
 
[DB2/NT] SQL1182N  User defined function "F2" could not 
initialize data source object of specified OLE DB provider. 
 HRESULT="0x80040e52". Diagnostic text: "Data source object is 
already initial".  SQLSTATE=38506
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All DB2 V9.7 users.                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* If a select query is executed against 2 or more OLEDB table  * 
* functions that references the same data source, error        * 
* returned.                                                    * 
*                                                              * 
* [DB2/NT] SQL1182N  User defined function "F2" could not      * 
* initialize data source object of specified OLE DB provider.  * 
*                                                              * 
* HRESULT="0x80040e52". Diagnostic text: "Data source object   * 
* is already initial".  SQLSTATE=38506                         * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to V9.7 FP2.                                         * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
First fixed in DB2 V9.7 FP2.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
12.11.2009
30.06.2010
30.06.2010
Problem solved at the following versions (IBM BugInfos)
9.7.FP2
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.2 FixList