DB2 - Problem description
Problem IC66407 | Status: Closed |
APPLICATION CRASH IN DB2APP.DLL IF TIMEOUT HAPPENS IN A MULTI-THREAD APPLICATION | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
If you have a long running query in your multi-threaded application that is interrupted due to a timeout, your application could crash in db2app.dll. The crash is happening in the external function api - SQLExecuteDirectW. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * when a long running query is interrupted by a timeout, in * * amultithreaded VB application. * **************************************************************** * PROBLEM DESCRIPTION: * * If you have a long running query in your * * multi-threadedapplication that is interrupted due to a * * timeout, yourapplication could crash in db2app.dll. The * * crash ishappening in the external function api - * * SQLExecuteDirectW. * **************************************************************** * RECOMMENDATION: * * Upgrade to db2_v95fp6 or db2_v97fp2 or higher release level. * **************************************************************** | |
Local Fix: | |
increase timeout - optimize the query. | |
available fix packs: | |
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows | |
Solution | |
db2_v95fp6 and db2_v97fp2 contains the fix of this problem. After the fix, the VB application will not crash. | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 19.02.2010 14.05.2010 14.05.2010 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.2 |