DB2 - Problem description
Problem IC66633 | Status: Closed |
DB2CMD PERFORMANCE ISSUE | |
product: | |
DB2 FOR LUW / DB2FORLUW / 950 - DB2 | |
Problem description: | |
V9.5 db2cmd takes more time for executing the same SQL statement compared with V9.1 or V8.2 in the same condition. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * User using CLP interface. * **************************************************************** * PROBLEM DESCRIPTION: * * DESCRIPTION: * * V9.5 db2cmd takes more time for executing the same SQL * * statement * * compared with V9.1 or V8.2 in the same condition. * * * * * * * * * * * * LOCAL FIX: * * * * Use -f option for db2cmd instead specifying the SQL * * statement as * * the parameter of db2cmd if many number of SQL statements are * * * * executed using db2cmd. * **************************************************************** * RECOMMENDATION: * * Recommended to move to V9.5 Fix Pack 6. * **************************************************************** | |
Local Fix: | |
Use -f option for db2cmd instead specifying the SQL statement as the parameter of db2cmd if many number of SQL statements are executed using db2cmd. | |
available fix packs: | |
DB2 Version 9.5 Fix Pack 6a for Linux, UNIX, and Windows | |
Solution | |
The issue was fixed in V9.5 Fix Pack 6. | |
Workaround | |
not known / see Local fix | |
BUG-Tracking | |
forerunner : APAR is sysrouted TO one or more of the following: IC67540 IC67541 follow-up : | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 24.02.2010 17.05.2010 17.05.2010 |
Problem solved at the following versions (IBM BugInfos) | |
9.5.FP6 | |