home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IC68697 Status: Closed

FCM SENDER IS NOT SELECTING DESIGNATED NETWORK INTERFACE TO SEND DATA

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
If multiple network interfaces are available on a machine with 
multiple logical partitions (MLNs), and each logical partition 
is specified to use a designated network interface for 
inter-partition communication (ie, via the netname column in 
db2nodes.cfg), DB2 may not choose the designated network 
interface to send data across partitions; it would instead let 
the operating system (OS) choose interfaces that are deemed 
appropriate to use.  Depending on the actual workloads, this 
behavior can potentially be suboptimal for send traffic if the 
OS chose a single interface (or only a small subset) for all 
logical partitions rather than fully utilizing all available 
ones.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All of these criteria must be present for the problem to     * 
* occur:                                                       * 
* - DPF                                                        * 
* - MLNs                                                       * 
* - multiple network interfaces on a machine                   * 
* - user configured each logical partition to use a different  * 
* network interface (ie, via the netname column in             * 
* db2nodes.cfg).                                               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* If multiple network interfaces are available on a machine    * 
* with                                                         * 
* multiple logical partitions (MLNs), and each logical         * 
* partition                                                    * 
* is specified to use a designated network interface for       * 
*                                                              * 
* inter-partition communication (ie, via the netname column in * 
*                                                              * 
* db2nodes.cfg), DB2 may not choose the designated network     * 
*                                                              * 
* interface to send data across partitions; it would instead   * 
* let                                                          * 
* the operating system (OS) choose interfaces that are deemed  * 
*                                                              * 
* appropriate to use.  Depending on the actual workloads, this * 
*                                                              * 
* behavior can potentially be suboptimal for send traffic if   * 
* the                                                          * 
* OS chose a single interface (or only a small subset) for all * 
*                                                              * 
* logical partitions rather than fully utilizing all available * 
*                                                              * 
* ones.                                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to v97fp3 or later.                                  * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
Problem was first fixed in v97fp3.
Workaround
not known / see Local fix
BUG-Tracking
forerunner  : APAR is sysrouted TO one or more of the following: IC68775 
follow-up : 
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
18.05.2010
16.09.2010
16.09.2010
Problem solved at the following versions (IBM BugInfos)
9.7.FP3
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.3 FixList
9.7.0.3 FixList