DB2 - Problem description
Problem IC69147 | Status: Closed |
LOCK_WAIT_TIME REPORTED BY MONITOR TABLE FUNCTIONS WILL NOT UPDATE WHILE A LOCK IS HELD IF A LOCK TIMEOUT IS BEING USED. | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
If a lock timeout has been specified (either using the LOCKTIMEOUT db cfg parameter or the LOCKTIMEOUT special register), the lock_wait_time monitor element reported by the monitor table functions (such as MON_GET_UNIT_OF_WORK_METRICS) does not increase over time as the lock is held. The monitor element is only updated when the lock is released. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All platform * **************************************************************** * PROBLEM DESCRIPTION: * * See error description * **************************************************************** * RECOMMENDATION: * * Update to V9.7 FP3. * **************************************************************** | |
Local Fix: | |
available fix packs: | |
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows | |
Solution | |
DB2 V9.7 FP3 will contain the fix. | |
Workaround | |
not known / see Local fix | |
BUG-Tracking | |
forerunner : APAR is sysrouted TO one or more of the following: IC69173 follow-up : | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 10.06.2010 20.09.2010 20.09.2010 |
Problem solved at the following versions (IBM BugInfos) | |
9.7.FP3 | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.3 | |
9.7.0.3 |