DB2 - Problem description

Problem IC71160 Status: Closed

DB2 GOVERNOR WILL FORCE OFF DB2FW AND DB2LUSED PROCESS

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
db2 governor forcing db2 process under different users (for 
example): 
 
2010-08-27-00.01.47    0 FORCE      applname `db2fw10` authid 
`testuid` applid `*N0.DB2.12345` coord 0 (line 9)  Idle 100068 
 
2010-08-27-00.01.47    0 FORCE      applname `db2fw3` authid 
`testuid` applid `*N0.DB2.123456` coord 0 (line 9)  Idle 100068 
 
2010-08-27-00.01.47    0 FORCE      applname `db2fw9` authid 
`testuid` applid `*N0.DB2.1234567` coord 0 (line 9)  Idle 100068
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* DB2 GOVERNOR WILL FORCE OFF DB2FW AND DB2LUSED PROCESS       * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* db2 governor forcing db2 process under different users (for  * 
*                                                              * 
* example):                                                    * 
*                                                              * 
*                                                              * 
*                                                              * 
* 2010-08-27-00.01.47    0 FORCE      applname `db2fw10`       * 
* authid                                                       * 
* `testuid` applid `*N0.DB2.12345` coord 0 (line 9)  Idle      * 
* 100068                                                       * 
*                                                              * 
*                                                              * 
* 2010-08-27-00.01.47    0 FORCE      applname `db2fw3` authid * 
*                                                              * 
* `testuid` applid `*N0.DB2.123456` coord 0 (line 9)  Idle     * 
* 100068                                                       * 
*                                                              * 
*                                                              * 
* 2010-08-27-00.01.47    0 FORCE      applname `db2fw9` authid * 
*                                                              * 
* `testuid` applid `*N0.DB2.1234567` coord 0 (line 9)  Idle    * 
* 100068                                                       * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* First fixed if fix pack 4 of v9.7                            * 
****************************************************************
Local Fix:
n/a
available fix packs:
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
First fixed if fix pack 4 of v9.7
Workaround
not known / see Local fix
BUG-Tracking
forerunner  : APAR is sysrouted TO one or more of the following: IC73306 
follow-up : 
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
13.09.2010
05.04.2011
05.04.2011
Problem solved at the following versions (IBM BugInfos)
9.7.
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.4 FixList