home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IC75198 Status: Closed

MISSING CONVERSION FILES FOR 1208-819 NOR 1208-923

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
For client codepage 1208 there are no conversion files for 
1208-819 nor 1208-923. When client is unable to recreate the 
database in codepage 923 or 1208 then Euro conversion fails.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Clients using codepage 1208 connecting to databases created  * 
* with codepage ISO8859-1.                                     * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* There is no Euro support for clients running with codepage   * 
* 1208 connecting to database creatd with codepage ISO8859-1.  * 
* There are no conversion files for  1208-819 nor 1208-923.    * 
* When client is unable to recreate the database in codepage   * 
* 923 or 1208 then Euro conversion fails.                      * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade your DB2 client to fix pack 5.                       * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
The conversion files have been updated in DB2a v9.7 FP 5.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
23.03.2011
13.12.2011
13.12.2011
Problem solved at the following versions (IBM BugInfos)
9.7.FP5
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.5 FixList