DB2 - Problem description

Problem IC79156 Status: Closed

DB2 INSTALLATION COMPLETES WITH "MINOR ERROR" BUT NO ERROR FOUND
IN INSTALLLOG

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
DB2 install completes with the following warning: 
 
"WARNING: A minor error occurred while installing '<Product 
Name>' on this computer. Some features may not function 
correctly. " 
 
This can be caused by a failure in the installation of the ITMA 
component,  which triggers a "Minor Error" condition but does 
not report the error in the install log. 
 
To determine if ITMA is the cause of the minor error,  check 
the ITMA installation log for any error conditions or core 
dumps. 
 
A failed ITMA installation will not affect normal DB2 operation. 
However,  it may cause further warnings on instance update or 
migration.  Instructions for removing ITMA from a DB2 copy can 
be found in the Information Center here: 
 
http://publib.boulder.ibm.com/infocenter/db2luw/v9r5/topic/com.i 
bm.db2.luw.qb.server.doc/doc/t0054822.html
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users on DB2 v97 Fp5 and earlier                         * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 v97 FP6                                       * 
****************************************************************
Local Fix:
The ITMA component is only used by Data Studio Admin Console 
(DSAC). 
 
If ITMA is not required,  it can be removed from the install 
media by removing the entire db2/<platform>/itma directory.
available fix packs:
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
First Fixed in db2 v97 Fp6
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
11.10.2011
11.06.2012
11.06.2012
Problem solved at the following versions (IBM BugInfos)
9.7.FP6
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.6 FixList