DB2 - Problem description
Problem IC80392 | Status: Closed |
MEANINGLESS EVENT RECORD MIGHT BE LOGGED IN WINDOWS APPLICATION EVENT LOG | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
When DB2 Remote Command Server Service starts up in Windows environment, a meaningless event record might be logged in Windows Application Event Log. The following is an example of the event record in XML format. <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"> <System> <Provider Name="DB2REMOTECMD_DB2COPY1" /> <EventID Qualifiers="49152">1</EventID> <Level>4</Level> <Task>0</Task> <Keywords>0x80000000000000</Keywords> <TimeCreated SystemTime="2011-11-09T13:26:00.000000000Z" /> <EventRecordID>12762</EventRecordID> <Channel>Application</Channel> <Computer>mycomputer.ibm.com</Computer> <Security /> </System> <EventData> <Data>rcmdTcpipListener</Data> <Data>Failed to configure listener's socket address. Check for port (db2ccmsrv) in SERVICES file, rc = 118423736.</Data> <Data> </Data> <Data> </Data> <Data> </Data> <Data> </Data> <Data> </Data> <Data> </Data> <Data> </Data> <Data> </Data> </EventData> </Event> The customer can ignore the above record safely. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * DB2 Server on Windows platform. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to V9.7 Fix Pack 6. * **************************************************************** | |
Local Fix: | |
The user can disable auto start-up of DB2 Remote Command Server Service if it is not used. | |
available fix packs: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
Solution | |
Problem was first fixed in Version 9.7 Fix Pack 6. | |
Workaround | |
The user can disable auto start-up of DB2 Remote Command Server Service if it is not used. | |
BUG-Tracking | |
forerunner : APAR is sysrouted TO one or more of the following: IC84468 follow-up : | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 13.12.2011 05.06.2012 05.06.2012 |
Problem solved at the following versions (IBM BugInfos) | |
9.7.FP6 | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.6 |