DB2 - Problem description
Problem IC81039 | Status: Closed |
DB2 MAY ABEND WITH SIGSEV WHEN USING XMLTABLE FUNCTION | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
DB2 may abend with memory corruption error while running a PL/SQL stored procedure using XMLTABLE function. DB2 stack dumps may look like this: STACK 1: resetAutomaton__14XmlnvAutomatonFbT1 + 0xEC startFragment__14XmlnvAutomatonFb + 0x40 m_startNavOnContext__14XmlnvNavigatorFP17xmlDataDescriptorb + 0x58C openNavigator__14XmlnvNavigatorFP17xmlDataDescriptorP8sqlrr_cb + 0x940 sqlriXMLScan__FP8sqlrr_cb + 0x530 sqlriExecThread__FP8sqlrr_cbP12sqlri_opparm@glue14CF + 0x168 sqlrihsjn__FP8sqlrr_cb + 0x14 sqlriSectInvoke__FP8sqlrr_cbP12sqlri_opparm + 0x628 sqlrr_process_fetch_request__FP14db2UCinterface + 0x188 sqlrr_fetch__FP14db2UCinterfaceP15db2UCCursorInfo + 0x408 csmDriveFetch__FP14db2UCinterfaceP15db2UCCursorInfobT3 + 0x354 csmFetch__FP14db2UCinterfaceP15db2UCCursorInfo + 0x15B4 fetchCursor__10pvmPackageFP14db2UCinterfaceCUi + 0xD4 executeSection__10pvmPackageFP5sqlcaUib + 0x260 executeQuery__3PVMFUib + 0x1A4 fetchCursorVariable__3PVMFCUiN31 + 0x3A8 run__3PVMFv + 0xCD8 pvm_entry + 0x1DC sqloInvokeFnArgs + 0xC4 sqloInvokeFnArgs@glue4AF + 0x78 sqlriInvokerTrusted__FP10sqlri_ufobP21sqlriRoutineErrorIntf + 0x1D0 OR STACK 2: sqloCrashOnCriticalMemoryValidationFailure SQLO_MEM_POOL::diagnoseMemoryCorruptionAndCrash sqloDiagnoseFreeBlockFailure sqlofmblkEx XmlnvTupleConstructor::destroyTupleConstructor XmlnvAutomaton::destroyAutomaton XmlnvNavigator::destroyNavigator XmlnvNavigator::destroyNavigator sqlricjpInfrequent sqlricjp sqlri_hsjnClose sqlrihsjn sqlriSectInvoke sqlrr_process_fetch_request sqlrr_fetch csmDriveFetch csmFetch pvmPackage::fetchCursor pvmPackage::executeSection PVM::executeQuery PVM::fetchCursorVariable PVM::run pvm_entry sqloInvokeFnArgs sqloInvokeFnArgs@glue4AF sqlriInvokerTrusted sqlriInvokeInvoker sqlricall sqlriSectInvoke sqlrr_process_execute_request sqlrr_execute.fdpr.clone.1791 sqljs_ddm_excsqlstt.fdpr.clone | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All users on DB2 v97 FP5 and earlier * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 v97 FP6 * **************************************************************** | |
Local Fix: | |
NO LOCAL FIX | |
available fix packs: | |
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows | |
Solution | |
First Fixed in DB2 v97 FP6 | |
Workaround | |
not known / see Local fix | |
BUG-Tracking | |
forerunner : APAR is sysrouted TO one or more of the following: IC81088 IC81205 IC81207 IC84334 IC84656 follow-up : | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 27.01.2012 26.06.2012 26.06.2012 |
Problem solved at the following versions (IBM BugInfos) | |
9.7.FP6 | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.6 |