home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IC81941 Status: Closed

ON WINDOWS VISTA (or above), DSDRIVER FAILS TO CONNECT TO LOCAL DATABASE.

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
On Windows Vista ( or above ), connect to database fails when: 
(1) connection is local, using IPC 
(2) DB2 server has Extended Security set to YES 
(3) DB2 server service runs under "Local System" or any other 
userid other than the user that is connecting. 
 
Connect fails. 
Error is -1032. Database manager not started.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Windows Vista DSDriver users                                 * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* On Windows Vista ( or 2008 ), connect to database fails      * 
* when:                                                        * 
* (1) connection is local, using IPC                           * 
* (2) DB2 server has Extended Security set to YES              * 
* (3) DB2 server service runs under "Local System" or any      * 
* other                                                        * 
* userid other than the user that is logged on.                * 
*                                                              * 
* Connect fails.                                               * 
* Error is -1032. Database manager not started.                * 
*                                                              * 
* The reason is because the client fails to establish the      * 
* correct                                                      * 
* DB2NAMESPACE.                                                * 
*                                                              * 
* The code incorrectly uses the SID file underneath it's own   * 
* installedcopy. It should use the SID file under the target   * 
* installedcopy.                                               * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 9.7 Fix pack 6                                * 
****************************************************************
Local Fix:
Use tcpip loopback to avoid IPC connection.
available fix packs:
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
Fixed in DB2 9.7 Fix pack 6
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.03.2012
04.06.2012
04.06.2012
Problem solved at the following versions (IBM BugInfos)
9.7.FP6
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.6 FixList