DB2 - Problem description
Problem IC83888 | Status: Closed |
USING A COLUMN WITH EXPLICIT INLINE LENGTH MAY CAUSE BUFFER OVERRUN | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
DB2 supports specification of an inline length for a column of type XML/LOB/user defined type. Under the scenario where this column is used as an input to a function, DB2 might ignore the inline length specification and use the default length for the datatype. This can lead to buffer overruns and memory corruption if the data length exceeds the default datatype length. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Please upgrade to DB2 version 970 fixpack 7 * **************************************************************** | |
Local Fix: | |
available fix packs: | |
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows | |
Solution | |
Fixed in DB2 version 970 fixpack 7 | |
Workaround | |
not known / see Local fix | |
BUG-Tracking | |
forerunner : APAR is sysrouted TO one or more of the following: IC87885 follow-up : | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 31.05.2012 29.01.2013 29.01.2013 |
Problem solved at the following versions (IBM BugInfos) | |
9.7.0 | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.7 |