DB2 - Problem description
| Problem IC88607 | Status: Closed | 
| GET SNAPSHOT MAY REPORT A VERY HIGH INCORRECT VALUE FOR "APPLICATION CONNECTS" | |
| product: | |
| DB2 FOR LUW / DB2FORLUW / A10 - DB2 | |
| Problem description: | |
| "db2 get snapshot for database on DBNAME" may report a very high 
"Application Connects" value, 4294967295 in following example. 
 
Here is an example of the snapshot: 
---------------------------------- 
              Database Snapshot 
 
Database name                              = SAMPLE 
Database path                              = /home/.... 
Input database alias                       = SAMPLE 
Database status                            = Active 
Catalog database partition number          = 0 
Catalog network node name                  = 
Operating system running at database server= AIX 64BIT 
Location of the database                   = Local 
First database connect timestamp           = 02/05/2012 ... 
Last reset timestamp                       = 02/05/2012 ... 
Last backup timestamp                      = 02/03/2012 ... 
Snapshot timestamp                         = 02/05/2012 ... 
 
Number of automatic storage paths          = 1 
Automatic storage path                     = /home/db2inst1 
      File system ID                       = 92233722172434... 
      Storage path free space (bytes)      = 3074293760 
      File system used space (bytes)       = 79822848 
      File system total space (bytes)      = 3221225472 
 
High water mark for connections            = 5 
Application connects                       = 4294967295 <<---- 
Secondary connects total                   = 4 
Applications connected currently           = 0 
Appls. executing in db manager currently   = 0 
Agents associated with applications        = 4 
Maximum agents associated with applications= 5 
Maximum coordinating agents                = 5 
---------------------------------- 
 
- This problem exists on any DB2 version, v9.1, v9.5 and v9.7. 
- The incorrect value reported in snapshot is due to an error in 
'reset monitor' internal processing. 
- The fix of APAR will modify the reset monitor behavior so that 
subsequent snapshots report Application connects value 
correctly. 
- There is no side effect by this APAR. 
- There is no work around but if users execute it again later, 
  it may report correct value since the problem is a timing 
  issue. | |
| Problem Summary: | |
| **************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Recommended to upgrade to DB2 for LUW v10.1 FP2 * **************************************************************** | |
| Local Fix: | |
| available fix packs: | |
| DB2 Version 10.1 Fix Pack 2 for Linux, UNIX, and Windows | |
| Solution | |
| Fix available from v101fp2 onwards. | |
| Workaround | |
| not known / see Local fix | |
| Timestamps | |
| Date - problem reported : Date - problem closed : Date - last modified : | 27.11.2012 01.01.2013 01.01.2013 | 
| Problem solved at the following versions (IBM BugInfos) | |
| Problem solved according to the fixlist(s) of the following version(s) | |
| 10.1.0.2 |  | 
| 10.5.0.2 |  | 







 