DB2 - Problem description

Problem IC88670 Status: Closed

CLP & CLI NOT PERFORMING CODE PAGE CONVERSION ON DATE, TIME and
TIMESTAMP VALUES FROM ZOS when IDAA Query Acceleration is enable

product:
DB2 CONNECT / DB2CONNCT / A10 - DB2
Problem description:
When using IDAA (DB2 Analytics Accelerator) with DB2 for z/OS 
and QUERY ACCELERATION = ENABLE is set, then the values of date, 
time and timestamp columns are not displayed correctly by either 
CLP or CLI clients. This issue exist with all non-JAVA clients. 
 
Here is an example query and its output when IDAA query 
acceleration is enabled: 
 
select birth_date, count(*) from sample.personnel for fetch only 
    BIRTH_DATE 
    ----------       ----------- 
    ...??..??.       20199 
    ...??..??        6028 
    .?.?..??.        337 
 
The problem does not occur when IDAA QUERY ACCELERATION = NONE 
is set.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* When C-client is used to access IDAA.                        * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to db2_v101fp2 or later releases.                    * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 10.1 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 10.1 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 10.1 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 10.1 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 10.1 Fix Pack 6 for Linux, UNIX, and Windows

Solution
db2_v101fp2 contains fix of this issue. After fix, the date data 
will display in correct format.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
28.11.2012
31.12.2012
28.11.2013
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
10.1.0.2 FixList
10.5.0.2 FixList