home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IC91246 Status: Closed

HADR PRIMARY DISCONNECTS AND STANDBY SHOWS PEER STATE WHEN DISK IS FULL ON
STANDBY.

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
HADR primary disconnects and standby shows peer state when disk 
is full on standby. 
 
On HADR standby, you can see the following error messages in 
db2diag.log file: 
 
2013-02-18-03.38.48.605355-360 I15634A387         LEVEL: Error 
PID     : 7995640              TID  : 10539       PROC : db2sysc 
0 
INSTANCE: db2inst1               NODE : 000 
EDUID   : 10539                EDUNAME: db2hadrs (SAMPLE) 0 
FUNCTION: DB2 UDB, data protection services, sqlpgifl, probe:50 
RETCODE : ZRC=0x850F000C=-2062614516=SQLO_DISK "Disk full." 
          DIA8312C Disk was full. 
... 
 
2013-02-18-03.53.28.302067-360 I47492A448         LEVEL: Info 
PID     : 7995640              TID  : 10539       PROC : db2sysc 
0 
INSTANCE: db2inst1               NODE : 000 
EDUID   : 10539                EDUNAME: db2hadrs (SAMPLE) 0 
FUNCTION: DB2 UDB, data protection services, sqlpgStartMfhEntry, 
probe:7240 
DATA #1 : <preformatted> 
Dual log array is full.  Checking if any new logs have been 
archived. 
end: 6139, lowestUnarchivedExtNum: 6074, path: 9
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* First fixed in DB2 Version 9.7 Fix Pack 9                    * 
****************************************************************
Local Fix:
Clear the disk full situation and restart the HADR standby.
available fix packs:
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
First fixed in DB2 Version 9.7 Fix Pack 9
Workaround
not known / see Local fix
BUG-Tracking
forerunner  : APAR is sysrouted TO one or more of the following: IC97543 IC97550 
follow-up : 
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
02.04.2013
17.12.2013
25.04.2014
Problem solved at the following versions (IBM BugInfos)
9.7.FP9
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.9 FixList
9.7.0.9 FixList