DB2 - Problem description
Problem IC95368 | Status: Closed |
THE UNINSTALLER OF 64-BIT DATA SERVER CLIENT/DRIVER DOESN'T REMOVE 32BIT ODBC DATA SOURCES. | |
product: | |
DB2 FOR LUW / DB2FORLUW / A50 - DB2 | |
Problem description: | |
Under 64-bit Windows OS uninstallation process leaves 32-bit ODBC data source created by the client/driver. The problem doesn't apply to 64-bit ODBC data sources. Local fix is to manually delete a leftover registry keys. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All DB2 V10.5 on LUW users. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to DB2 V10.5 Fix Pack 3 or higher. * **************************************************************** | |
Local Fix: | |
Manually delete a leftover registry keys. The default location is: HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ODBC\ODBC.INI. | |
available fix packs: | |
DB2 Version 10.5 Fix Pack 3 for Linux, UNIX, and Windows | |
Solution | |
Problem Fixed In DB2 V10.5 Fix Pack 3 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 27.08.2013 07.04.2014 07.04.2014 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) | |
10.5.0.3 | |
10.5.0.3 |