DB2 - Problem description

Problem IC96180 Status: Closed

DB2 MIGHT ABEND WHILE COMPILING SQL QUERY.

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
DB2 might abend ( with SIGSEGV ) while compiling a SQL query. 
The symptoms of this issue are as follows: 
 
1) There are indexes available on one or more tables involved in 
the query. 
 
2) The stack trace may look like one of the following: 
 
      sqlno_btree_preds 
      sqlno_index_scan 
      sqlno_crule_index_scan 
      sqlno_crule_index_scan 
      sqlno_crule_access_root 
      sqlno_crule_access 
      sqlno_crule_access 
      sqlno_find_plan_chain 
      sqlno_get_best_plan 
      sqlno_crule_nljn_inner 
 
      OR 
 
      sqlno_get_best_key_cond 
      sqlno_build_keycond 
      sqlno_find_key_preds 
      sqlno_btree_preds 
      sqlno_index_scan 
      sqlno_crule_index_scan 
      sqlno_crule_index_scan 
      sqlno_crule_access_root 
      sqlno_crule_access 
      sqlno_crule_access 
      sqlno_find_plan_chain 
      sqlno_get_best_plan 
      sqlno_crule_nljn_inner
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 9.7 Fix Pack 9                                * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
This will be first fixed on DB2 9.7 Fix Pack 9.
Workaround
not known / see Local fix
BUG-Tracking
forerunner  : APAR is sysrouted TO one or more of the following: IC97044 IC97063 
follow-up : 
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
23.09.2013
04.02.2014
04.02.2014
Problem solved at the following versions (IBM BugInfos)
9.7.FP9
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.9 FixList