DB2 - Problem description
Problem IC97081 | Status: Closed |
CLUSTER CACHING FACILITY FAILS TO START | |
product: | |
DB2 FOR LUW / DB2FORLUW / A50 - DB2 | |
Problem description: | |
This issue is a result of failure of dlopen on vios, where there is a library (libviocmnotify.a) that gets opened while opening CF libraries. The pureScale cluster will not be able to start the Cluster Caching Facility. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * N/A * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to 10.5.0.3 * **************************************************************** | |
Local Fix: | |
available fix packs: | |
DB2 Version 10.5 Fix Pack 3 for Linux, UNIX, and Windows | |
Solution | |
Problem Fixed In 10.5.0.3 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 21.10.2013 03.09.2014 03.09.2014 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) | |
10.5.0.3 | |
10.5.0.3 |