DB2 - Problem description
Problem IC97606 | Status: Closed |
BACKUP LIST UTILITIES COMPLETED WORK ESTIMATE INACCURATE WHEN BACKUP-COMPRESSION ENABLED. | |
product: | |
DB2 FOR LUW / DB2FORLUW / A50 - DB2 | |
Problem description: | |
The LIST UTILITIES 'Completed Work' metric (which is displayed via 'db2 list utilities' or 'db2pd -utilities') during Backup with compression is inaccurate, which makes it difficult to gauge how close to completion a backup is. The 'Completed Work' value will climb steadily while the backup is running. However, before approaching anywhere close to the Total Work estimate, the backup will suddenly complete and only then will the 'Completed Work' value reflect the Total Work estimate. This can be easily observed by running a Backup with compression, and viewing 'db2pd -utilities' output every second. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to inclusive fixpack. * **************************************************************** | |
Local Fix: | |
available fix packs: | |
DB2 Cancun Release 10.5.0.4 (also known as Fix Pack 4) for Linux, UNIX, and Windows | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 12.11.2013 08.09.2014 08.09.2014 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) | |
10.5.0.4 |