DB2 - Problem description
Problem IC99060 | Status: Closed |
POSSIBLE ABEND OF DB2PCLNR DUE TO SIGSEGV IN SQLBCLNRCONDLATCHPAGE OR SQLBCLNRGATHERFORTHRESH | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
Under rare timing conditions, DB2 engine (EDU db2pclnr) might abend with SIGSEGV in the following stack: AIX: sqlbClnrCondLatchPage sqloDispatchNBlocks or sqlbClnrCondLatchPage sqlbClnrDispatchSomeAIO or sqlbClnrCondLatchPage Other platforms: sqlbClnrGatherForThresh sqlbClnrGatherPages sqlbClnrEntryPoint sqbPgClnrEdu::RunEDU | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 version 9.7 Fix Pack 10 or higher. * **************************************************************** | |
Local Fix: | |
Enable alternative page cleaning: db2set DB2_USE_ALTERNATE_PAGE_CLEANING=ON | |
Solution | |
Fixed in DB2 version 9.7 Fix Pack 10. | |
Workaround | |
not known / see Local fix | |
BUG-Tracking | |
forerunner : APAR is sysrouted TO one or more of the following: IC99216 follow-up : | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 29.01.2014 09.12.2014 09.12.2014 |
Problem solved at the following versions (IBM BugInfos) | |
9.7.FP10 | |
Problem solved according to the fixlist(s) of the following version(s) | |
9.7.0.10 |