Informix - Problem description

Problem IT02953 Status: Closed

ONBAR ABENDS IN BSAGETENVIRONMENT CALL USING EMC NETWORKER STORAGE MANAGER

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Onbar using EMC NetWorker storage manager can abort immediately 
after connecting to storage manager. 
A dependency on BAR_DEBUG setting has been observed, but this is 
deemed purely accidental. 
 
bar_act.log might contain: 
 2014-06-23 09:56:57 9650  9644 Using EMC's NetWorker XBSA 
version 1.0 as the Storage Manager. XBSA API version is 1.0.1. 
 2014-06-23 09:56:57 9650  9644 Working with networker xbsa as 
generic storage manager. 
 2014-06-23 09:56:58 9650  9644 Successfully connected to 
Storage Manager. 
 2014-06-23 09:56:58* 9650  9644 ASSERT: file bar_unix.c line 
1316 - contact product support 
 
No meaningful bar_debug output could be obtained as setting 
BAR_DEBUG to anything higher than 1 would have avoided the 
problem. 
 
Closer inspection showed the crash is occurring in an initial 
call to BSAGetEnvironment() XBSA function.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Users using onbar with storage managers other than TSM and   * 
* PSM.                                                         * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.xC5                      * 
****************************************************************
Local Fix:
An easy workaround is setting IFX_BAR_NO_LONG_BUFFERS 
environment variable.
Solution
Problem Fixed In IBM Informix Server 12.10.xC5
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
03.07.2014
19.01.2016
19.01.2016
Problem solved at the following versions (IBM BugInfos)
12.10.xC5
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5 FixList
12.10.xC5.W1 FixList