DB2 - Problem description

Problem IT04362 Status: Closed

SQLCODE -302 IS RETURNED DURING STATIC SQL EXECUTION INSTEAD OF BIND/REBIND

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
Binding or rebinding a static application should detect invalid 
host variable information (such as a DECIMAL with precision 0) 
and return SQLCODE -302. 
In some circumstances, the invalid host variable information may 
not be detected at bind/rebind, and is recorded in the section. 
 
This results in SQLCODE -302 at execution time instead.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 version 9.7 fix pack 11                       * 
****************************************************************
Local Fix:
Ensure host variable information is valid
Solution
First fixed in DB2 version 9.7 fix pack 11
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
12.09.2014
19.10.2015
19.10.2015
Problem solved at the following versions (IBM BugInfos)
9.7.FP11
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.11 FixList