Informix - Problem description

Problem IT04983 Status: Closed

IDS_INSTALL OPTION -DOVERWRITE_PRODUCT NEEDS TO BE DOCUMENTED

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Some times the ids_install would return the following error: 
 
Additional Notes: WARNING - The install application has detected 
a conflicting product installed in the specified install 
location. 
Pass -DOVERWRITE_PRODUCT=true on the command line to bypass this 
check. 
 
But this option is not documented.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Informix 12.10                                               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* See Problem Conclusion.                                      * 
****************************************************************
Local Fix:
Solution
You can use the -DOVERWRITE_PRODUCT=TRUE silent installation 
option to bypass the check for a conflicting product 
installations.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
16.10.2014
16.10.2015
16.10.2015
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5 FixList