Problem IT05278 Status: Closed

XI/NOTIFY RESET USES CONNECTION ON DOWN PORT

product:
DB2 FOR LUW / DB2FORLUW / A10 - DB2
Problem description:
If a port on an RDMA card becomes unavailable (for example, a 
cable is removed), pureScale can potentially attempt to reuse 
connections established through that port. These connections are 
no longer valid, but each attempted use will result in a 15 
second timeout before the connection is torn down, and a 
different connection in the cache is attempted. 
 
This apar fix will first check the status of the port before 
using a connection.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* See Error Description                                        * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to V10.1 FP5 for this APAR fix.                      * 
****************************************************************
Local Fix:
Solution
See Error Description
Workaround
not known / see Local fix