home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Latest versionsfixlist
14.10.xC11 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

Informix - Problem description

Problem IT05878 Status: Closed

COLUMN NAME IN TSCONTAINERTABLE EXCEEDING 18 BYTES COULD BLOCK MIGRATION

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
A value in column name in tscontainertable which exceeds 18 
bytes could block the migration. 
 
Message in the online.log: 
08:46:57  Conv/rev: blade conversion failed. See 
$INFORMIXDIR/etc/conv/convblade1210xC4.out 
 
convblade1210xC4.out: 
EXECUTE FUNCTION SYSBldPrepare('any','migrate'); 
(U0001) - registerBlade - Unable to register TimeSeries.6.00.FC4 
- unknown error - check online log and sysblderrorlog table for 
more information
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* TimeSeries                                                   * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IDS-12.10.xC5                                      * 
****************************************************************
Local Fix:
Solution
Problem Fixed In IDS-12.10.xC5
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
02.12.2014
16.10.2015
16.10.2015
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5 FixList
12.10.xC5.W1 FixList