Informix - Problem description

Problem IT06589 Status: Closed

MIGRATION FROM 12.10.FC3 TO 12.10.FC4W1 COULD LEAD TO -9793 USER DEFINED
ROUTINE (UPDATE) MODULE LOAD FAILED

product:
IFMX ULT WHSE E / IM0019BOS / C10 - IDS 12.10
Problem description:
After a migration from 12.10.FC3 to 12.10.FC4W1 a 
PutElemNoDups() fails with -9793 User Defined Routine (update) 
module load failed. 
 
Message in the online.log 
 
10:18:22  Loading Module 
<$INFORMIXDIR/extend/TimeSeries.6.00.FC3/TimeSeries.bld> 
10:18:22  (2): The C Language Module 
<$INFORMIXDIR/extend/TimeSeries.6.00.FC3/TimeSeries.bld> can't 
load 
    reason: Cannot access library file
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* 12.10.xC4, 12.10.xC4W1, 12.10.xC4w2, 12.10.xC5               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.xC6                      * 
****************************************************************
Local Fix:
Solution
Problem Fixed In IBM Informix Server 12.10.xC6
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
19.01.2015
30.12.2015
30.12.2015
Problem solved at the following versions (IBM BugInfos)
12.10.xC6
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5.W1 FixList
12.10.xC6 FixList