home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36
Latest versionsfixlist
14.10.xC11 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

Informix - Problem description

Problem IT06735 Status: Closed

ONPSM DOES NOT WORK WITH EFFECTIVE GROUP ID SET TO BARGROUP - RETURNING
-88300

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
onpsm does not work with effective group id set to "bargroup". 
While onbar works with effective group id set to "bargroup", 
onpsm returns: 
 
Error -88300: The current user does not have authorization to 
run this utility.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Informix 12.10                                               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* See Problem Conclusion.                                      * 
****************************************************************
Local Fix:
Solution
To run the onpsm utility, you must be user root or informix.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
26.01.2015
16.10.2015
16.10.2015
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5 FixList
12.10.xC5.W1 FixList