Informix - Problem description
Problem IT07094 | Status: Closed |
ENTERPRISE REPLICATION HANG POSSIBLE IN DATASYNC APPLY THREAD (RQMDECREMENTUSE -> MT_SPIN_LOCK_WAIT) | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Using 12.10.FC4 an identical ER target hang has been observed repeatedly, with one of the CDRD_* threads permanently 'running' in following stack: __fd_poll mt_spin_lock_wait() rqmDecrementUse() rqmUpdateHandleHelper() rqmGetTxnByStamp() rmiGetNextPendingTxn() rmNextMsg() dsiResolverThread() cdrTrampolineThread() th_init_initgls() startup() | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC5 * **************************************************************** | |
Local Fix: | |
Solution | |
Problem Fixed In IBM Informix Server 12.10.xC5 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 11.02.2015 16.10.2015 16.10.2015 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC5 | |
Problem solved according to the fixlist(s) of the following version(s) | |
12.10.xC5 | |
12.10.xC5.W1 |