Informix - Problem description

Problem IT07094 Status: Closed

ENTERPRISE REPLICATION HANG POSSIBLE IN DATASYNC APPLY THREAD
(RQMDECREMENTUSE -> MT_SPIN_LOCK_WAIT)

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Using 12.10.FC4 an identical ER target hang has been observed 
repeatedly, with one of the CDRD_* threads permanently 'running' 
in following stack: 
 
__fd_poll 
mt_spin_lock_wait() 
rqmDecrementUse() 
rqmUpdateHandleHelper() 
rqmGetTxnByStamp() 
rmiGetNextPendingTxn() 
rmNextMsg() 
dsiResolverThread() 
cdrTrampolineThread() 
th_init_initgls() 
startup()
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users                                                    * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.xC5                      * 
****************************************************************
Local Fix:
Solution
Problem Fixed In IBM Informix Server 12.10.xC5
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
11.02.2015
16.10.2015
16.10.2015
Problem solved at the following versions (IBM BugInfos)
12.10.xC5
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5 FixList