Informix - Problem description
Problem IT07389 | Status: Closed |
USING XTRACE -C XTF_LC -F XTF_DEBUG CAN CAUSE A READ AHEAD THREAD TO ASSERT FAILURE SEGV IN RA_DO_LC_REQ() | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Stack trace: 11:46:59 Stack for thread: 63 readahead_0 base: 0x0000000348358000 len: 69632 pc: 0x0000000001393ae6 tos: 0x0000000001cc4dd0 state: running vp: 12 afstack mt_ex_throw_sig afsig_handler <signal frame> ra_do_lc_req readahead_daemon th_init_initgls startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * any users of xtrace with XTF_LC * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
Local Fix: | |
Solution | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 27.02.2015 30.12.2015 30.12.2015 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC6 | |
Problem solved according to the fixlist(s) of the following version(s) | |
12.10.xC6 |