DB2 - Problem description

Problem IT07583 Status: Closed

MONITOR DATA OF BP_HITRATIO MAY RETURN WRONG RESULT

product:
DB2 FOR LUW / DB2FORLUW / A10 - DB2
Problem description:
Monitor Metrics collected from BP_HITRATIO can return slight 
wrong data in some cases. 
TOTAL_HIT_RATIO, DATA_HIT_RATIO, INDEX_HIT_RATIO and 
XDA_HIT_RATIO may return higher value than actual. 
reason to hit is to not reduce the number of POOL_ASYNC_DATA_ 
READS, POOL_ASYNC_INDEX_ READS, POOL_ASYNC_XDA_ READS from 
corresponding calculations.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users using V10.1 and BP_HITRATIO() Table Function       * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to db2_v101fp5 to resolve this                       * 
****************************************************************
Local Fix:
There is apparently no local fix for it.
Solution
Upgrade to db2_v101fp5 to use the correct formulas
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.03.2015
13.07.2015
13.07.2015
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
10.1.0.5 FixList