Informix - Problem description

Problem IT08724 Status: Closed

RECURSIVE EXCEPTION SELECTING ON A TIMESERIES VTI WITH TIMESERIES WHICH ARE
MIGRATED FROM AN OLDER VERSION

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
A select from a timeseries VTI crashes the server with: 
 
17:04:31  Recursive Exception - Server exiting 
17:04:32  The Master Daemon Died 
17:04:32  PANIC: Attempting to bring system down
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* Informix server 12.10                                        * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.xC6                      * 
****************************************************************
Local Fix:
Solution
Problem Fixed In IBM Informix Server 12.10.xC6
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
05.05.2015
30.12.2015
30.12.2015
Problem solved at the following versions (IBM BugInfos)
12.10.xC6
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC6 FixList