Informix - Problem description
Problem IT10728 | Status: Closed |
MAIN_LOOP ABENDING IN NEED_TO_CKPT() WITH AUTO_CKPTS ON AND RAS_PLOG_SPEED VERY LOW | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
An 'fpe' floating-point-exception (or EXCEPTION_INT_DIVIDE_BY_ZERO on Windows) can occur in main_loop thread doing need_to_ckpt() shortly after engine fast recovery if using RTO_SERVER_RESTART, AUTO_CKPTS is On, RAS_LLOG_SPEED is 0 and RAS_PLOG_SPEED non-zero, but below 8. An engine configured this way will not be able to stay up for more than a few seconds after fast recovery completed. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * informix customers * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
Local Fix: | |
Increase onconfig RAS_PLOG_SPEED to >= 8 or set to 0. | |
Solution | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 17.08.2015 30.12.2015 30.12.2015 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC6 | |
Problem solved according to the fixlist(s) of the following version(s) | |
12.10.xC6 |