DB2 - Problem description

Problem IT10911 Status: Closed

I/O IN PDLOG() IS DELAYED WHEN THE PROCESS IS WORKING IN THE FENCED
OPERATION MODE ON PURESCALE.

product:
DB2 FOR LUW / DB2FORLUW / A50 - DB2
Problem description:
This delay causes the delay of db2sysc process termination and 
the recovery by ACR on the client after ConfigRM is damaged. 
The fix requires a new feature on pdLog() and the messages will 
be posted in the local storage file like syslog because 
db2diag.log is not available due to gpfs in fenced operation 
mode.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* pureScale user                                               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to db2 Version 10.5 FixPack 7 or higher              * 
****************************************************************
Local Fix:
Solution
Problem was first fixed in Version 10.5 FixPack 7
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
25.08.2015
20.01.2016
20.01.2016
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
10.5.0.7 FixList