home clear 64x64
en blue 200x116 de orange 200x116 info letter User
suche 36x36

Fix list for Informix Dynamic Server 11.50.xC2

Informix Dynamic Server provides periodic fixes for release 11.5. The following is a complete listing of fixes for Version 11.50.xC2.


NOTE: some detail links below have been disabled as they are no longer available.
APAR
Description
IC53825 THE SCAN_EH_FRAME (): BAD CIE REFERENCE MESSAGE IS PRINTED IN THE INFORMIX LOG FILE AFTER EXECUTING ONINIT
IC56245 ASTERISK DENOTING BLOCKED CHECKPOINT IN ONSTAT -G CKP INCORRECTLY DOCUMENTED
IC56332 FET_BUF_SIZE DOES NOT WORK WITH MODE-ANSI DATABASES UNLESS TRANSACTION IS SET TO READ ONLY
IC56608 WHEN A PREPARED STATEMENT IS EXECUTED, IT CONTINUES TO EXECUTE UNTIL SPL IS RE-COMPILED
IC56611 FILE/SOCKET DESCRIPTORS REACH 32,768 ON PRIMARY WITH RSS REPLICATION WHEN RSS NODE DEMOTED FROM HDR SECONDARY
IC56613 SELECT SEQUENCE_NAME.NEXTVAL HANGS ON HDR SECONDARY
IC56614 MACOS: CLICKING ON RELEASE NOTES LINK FROM THE IDS BUNDLE INSTALLER LAUNCHES THE BROWSER BUT GIVES NO PERMISSIONS ERROR
IC56615 MACOS: THE IDS INSTALLER DOES NOT AUTOMATICALLY CONFIGURE KERNEL SHARED MEMORY PARAMETERS, CAUSING SERVER INITIALIZATION TO FAIL
IC56616 MACOS: INFORMIX USER GETS INVALID HOME DIRECTORY ERROR MESSAGE AT LOGON, CANNOT OPEN TERMINAL
IC56734 DBWORKER AND DBSCHEDULER THREADS ON 11.50.FC1 GENERATE AF IN STMTMON_HOSTVARS() WHILE SQLTRACE LEVEL IS SET TO HIGH
IC56987 ONCMSM DOES NOT FAIL OVER WHEN CONFIGURED WITH THE S=6 SECURITY OPTION
IC57002 SYSTEM HANGS IN CHECKPOINT -- XCHG_* THREADS WAITING FOREVER IN CRITICAL SECTION DURING CREATE INDEX
IC57110 WINDOWS 2008: 64-BIT IDS 11.50.FC1 INSTALL FAILS ON WINDOWS SERVER 2008
IC57166 DBIMPORT ON WINDOWS 32BIT FAILS WHEN EXECUTING A CREATE TABLE STATEMENT WHEN A NON-DEFAULT DB_LOCALE IS USED.
IC57169 AN ALTER FRAGMENT ON TABLE ATTACH PARTITION COMMAND CAUSES THE IDS TO ASSERT FAIL
IC57171 MIGRATION FROM IDS 9.40 CAN LEAVE PHYSICAL LOG MARKER PAGES IN AN INSTANCE THAT ARE ACCIDENTIALLY PICKED UP LATER
IC57243 AF SELECTING FROM A VIEW WHICH CONTAINS A SELECT WITH A SUBQUERY USING SPL UDR
IC57245 IDS ABENDS WHEN EXECUTING THE AUS_EVALUATOR FUNCTION ANDEXT_DIRECTIVES=2 IS SET IN THE ONCONFIG
IC57271 VERCOLS ARE COUNTED IN NCOLS AND THIS DISAGREES WITH DOCUMENTATION
IC57304 FREQUENT -211 ON SYSPROCPLAN IN 10.00.XC8, 11.10.XC2 AND IN ABOVE VERSIONS
IC57311 PAGE CLEANERS SET TO 128 GIVES LOGICAL LOG LAYOUT MAY CAUSE ONLINE TO GET INTO LOCKED STATE ERROR MESSAGE
IC57436 AFTER UPGRADING FROM 10.00.XC7 TO 10.00.XC8 SQL STATEMENTS WITH OR CLAUSE ON NON_LEADING INDEX COLUMN MAY PERFORM SLOWER
IC57489 WIN64: CREATING AN INDEX HANGS
IC57497 AN UPDATABLE SECONDARY SERVER WILL CRASH IN CDRSTREAMBM_ALLOC() WHEN EXECUTING A DML ON A TABLE WITH A LARGE NUMBER OF ROWS
IC57549 USING DEFAULT VALUES FOR LVARCHAR STORED PROCEDURE PARAMETER CAUSES MEMORY CORRUPTION
IC57612 INSTALL: KEEPING DOMAIN INSTALL DURING UPGRADE DOES NOT WORK IF LOCAL INFORMIX USER IS NOT PRESENT