Informix - Problem description
Problem IT44867 | Status: Closed |
REDUCE CONTENTION ON DDH CHAIN MUTEX FOR OPERATIONS ON SAME DATABASE TABLE | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
when a large number of threads perform concurrent operations relating to the same database table and those threads require access to the table's data dictionary information, they may be required to wait for short periods of time prior to gaining access. This may be seen in the output of the commands "onstat -g lmx" or "onstat -g wmx" as a long list of waiting thread ids for "ddh_chain", generally with a wait time of zero seconds | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC11. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC11. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC11. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC11. * **************************************************************** | |
Comment | |
Fixed in Informix Server 14.10.xC11. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 31.10.2023 03.06.2024 03.06.2024 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |