Informix - Problem description

Problem IT35900 Status: Closed

WINDOWS: CSDK INSTALLATION CAN FAIL WITH A SEGV

product:
IBM CSDK / 5724C2381 / 450 - CSDK 4.50
Problem description:
installation CSDK on a Windows OS may end abruptly without any
error message.
Running the installation with "-DDEBUG_LEVEL=9
-DDEBUG_FILE=C:\'tmp\'debug.out" to generate debug information
shows that the install aborts when calling:

       2020-11-18 13:45:24 14772  8756 Native Install API
successfully initialized.
       2020-11-18 13:45:24 14772  8756 Entering the fourth
section in NativeAPI.InitNativeAPI()


It doesn't fail all the time, it depends on the memory layout.



-------------
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Client SDK prior to 4.10.xC15 and          *
* 4.50.xC6.                                                    *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Client SDK 4.10.xC15 (when available) or *
* 4.50.xC6 (when available).                                   *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Client SDK prior to 4.10.xC15 and          *
* 4.50.xC6.                                                    *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Client SDK 4.10.xC15 (when available) or *
* 4.50.xC6 (when available).                                   *
****************************************************************
Comment
Fixed in Informix Client SDK 4.10.xC15 and 4.50.xC6.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
15.02.2021
12.05.2021
12.05.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)