Informix - Problem description

Problem IT35916 Status: Closed

SELECT ON SYSSQLSTAT CAN END IN AN ENDLESS LOOP AND CAN BLOCK THE SESSION
MUTEX

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
When a select on syssqlstat is facing an internal issue, the
thread can end in an endless loop.
The thread is blocking the session mutex too.

Example for the select:
SELECT sqs_sqlerror, sqs_isamerror, count(*) num_sessions FROM
syssqlstat

Stack (taken with a debugger):

#0 0x00007f34cd8fe630 in sigprocmask () from /lib64/libc.so.6
#1 0x0000000001416833 in mt_sighold ()
#2 0x0000000001414387 in mt_ex_throw_sig ()
#3 0x000000000141e0c3 in afsig_handler ()
#4 
#5 0x000000000091c8fc in prsqlstat ()
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC6.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC6 (when available).                                  *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC6.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC6 (when available).                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC6.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
16.02.2021
18.05.2021
18.05.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)