Informix - Problem description

Problem IT36149 Status: Closed

SCHAPI: [AUTO UPDATE STATISTICS EVALUATION 42-2] ERROR -1265 OVERFLOW
OCCURRED ON A DATETIME OR INTERVAL OPERATION.

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
With tables having data distributions info, in sysdistrib
catalog table, that's older than ca. 11 years and 5 months
(99999 hours), AUS would throw following error:

SCHAPI: [Auto Update Statistics Evaluation 42-2] Error -1265
Overflow occurred on a datetime or interval operation.

Reason seems to be an HOUR(5) limitation in an internal query
populating sysadmin:aus_work_coldist transient table,
aus_coldist_expired field (which is a BIGINT, so could easily
hold higher numbers.)
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Local Fix:
determine and manually drop such old distribution info
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.03.2021
23.08.2021
23.08.2021
Problem solved at the following versions (IBM BugInfos)