Informix - Problem description

Problem IT39943 Status: Closed

THREAD ON PRIMARY OF HDR PAIR CAN HANG IN CDRLSQN_WAIT WHEN DRINTERVAL 0
AND HDR_TXN_SCOPE NEAR_SYNC

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
When you have a single sqlexec thread executing DML, it is
possible that it can hang for unexpectedly long
durations sleeping forever trying to commit in a stack
like:

0x0000000001c14ed2 (oninit) yield_processor_mvp
0x0000000001be7b09 (oninit) mt_yield
0x000000000150d54f (oninit) cdrLSNQ_Wait
0x0000000001780143 (oninit) hdrSyncTxnMode
0x00000000018af936 (oninit) proxyWaitForAllNodesFromPrimary
0x0000000000ff21a3 (oninit) rscommit
0x0000000001276298 (oninit) iscommit
0x00000000008a27c0 (oninit) sqiscommit
0x000000000083c6a0 (oninit) sqcommit
0x000000000077e667 (oninit) aud_sqcommit
0x0000000000c1e745 (oninit) sql_commit
0x0000000000c1e43b (oninit) sq_commit
0x0000000000d4c0e7 (oninit) sqmain
0x0000000001dbeecd (oninit) listen_verify
0x0000000001dbdf08 (oninit) spawn_thread
0x0000000001ba9c27 (oninit) th_init_initgls
0x0000000001c336ad (oninit) startup

The hang can be remedied simply enough through a log buffer
flush by some other session's
DML activity, but when this is the only thread executing DML it
may continue to hang until
either a checkpoint or possibly dbscheduler activity.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC16 and 14.10.xC8.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC16 or 14.10.xC8.          *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC16 and 14.10.xC8.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC16 or 14.10.xC8.          *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC16 and 14.10.xC8.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
11.02.2022
08.05.2023
08.05.2023
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)