Informix - Problem description

Problem IT40354 Status: Closed

INCORRECT BLOB SIZE IS PASSED TO SERVER RESULTING IN MEMORY OVERWRITE AND
CRASH WHEN BLOB IS COMPRESSED

product:
IBM CSDK / 5724C2381 / 450 - CSDK 4.50
Problem description:
An incorrect blob size is passed to the server resulting in a
memory overwrite and crash when the blob is compressed.

The client receives the correct uncompressed size of the blob it
is about to select however, when it fetches the blob it passes
the wrong size to the server, which results in a memory
overwrite during the uncompress operation.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Client SDK prior to version 4.50.FC8.      *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Client SDK 4.50.FC8.                     *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Client SDK prior to version 4.50.FC8.      *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Client SDK 4.50.FC8.                     *
****************************************************************
Comment
Fixed in Informix Client SDK 4.50.FC8.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
22.03.2022
07.04.2022
07.04.2022
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)