Informix - Problem description
Problem IC53825 | Status: Closed |
THE "SCAN_EH_FRAME (): BAD CIE REFERENCE" MESSAGE IS PRINTED IN THE INFORMIX LOG FILE AFTER EXECUTING ONINIT | |
product: | |
IBM IDS / 5724L2300 / B15 - IDS 11.50 | |
Problem description: | |
After you have executed the oninit executable, the following message is inserted in to the informix log file: 03:59:32 pid 15930: scan_eh_frame(): bad CIE reference | |
Problem Summary: | |
**************************************************************** USERS AFFECTED: users of IDS 11.10 or higher (64 bit) on Linux x86_64 on RH ES 5 or other recent Linux distributions **************************************************************** PROBLEM DESCRIPTION: When starting IDS, the mesage log log file shows following text: scan_eh_frame(): bad CIE reference **************************************************************** RECOMMENDATION: Upgrade to 11.10.FC3 when available or 11.50.FC2 **************************************************************** | |
Local Fix: | |
Solution | |
Problem is first fixed in IDS 11.10.FC3 / 11.50.FC2 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 19.09.2007 28.08.2008 28.08.2008 |
Problem solved at the following versions (IBM BugInfos) | |
11.10.FC3, 11.50.FC2 | |
Problem solved according to the fixlist(s) of the following version(s) | |
11.50.xC2 |