Informix - Problem description

Problem IT31200 Status: Closed

IN-PLACE ALTER CAN TAKE LONG, CONSUMING A FULL CPU VP, WHEN CLEANING UP
MANY (AND SOME LARGE) OLD ALTERS

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
An ALTER TABLE, when executed as an in-place alter (IPA), is the
point in time where oldest in-place alter versions get cleaned
up if there are no more rows for these versions.  Such clean-up
can be time and cpu consuming if there are many such old
versions to remove and esp. some later versions in the IPA
history involve large alters (e.g. multiple hundreds of columns
added in one version).  With fragmented tables this process had
to occur for every fragment's IPA history, and while processing
one partition, no other thread could be running on the current
cpu vp.

This is independent from any rows in such table and also has
nothing to do with 'outstanding in-place alters' (rows still in
old versions' schemas). No table data is being modified in this
process.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC5.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC5.                                                   *
****************************************************************
Local Fix:
To anticipate and avoid this problem, find tables with very high
(> couple thousands) sysmaster.sysptnhdr.pta_opems_filled values
and rebuild them before their next ALTER TABLE.
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.12.2019
10.12.2020
10.12.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
invispix 10x10
invispix 10x10
invispix 10x10
Technical InfoTechnical Info

Technical Info

DocumentationDocumentation

Documentation

IBM NewsletterIBM Newsletter

IBM Newsletter

Current BugsCurrent Bugs

Current Bugs

Bug ResearchBug Research

Bug Research

Bug FixlistsBug Fixlists

Bug Fixlists

Release NotesRelease Notes

Release Notes

Machine NotesMachine Notes

Machine Notes

Release NewsRelease News

Release News

Product LifecycleProduct Lifecycle

Lifecycle

Media DownloadMedia Download

Media Download

invispix 10x10
Service und SupportService und Support

Service and Support

Informix MonitoringInformix Monitoring

Informix Monitoring

Admin-Scout forInformixAdmin-Scout forInformix

Admin-Scout for Informix

Informix News & InfosInformix News & Infos

Informix News & Infos

This site uses cookies to make it easier for us to provide you with our services. By using our site you agree to the use of cookies.