Informix - Problem description
Problem IT31884 | Status: Closed |
ONBAR IS CRASHING WHILE WORKING WITH AMAZON AWS S3 FOR TEMPORARYREDIRECTION ERROR 307 | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
With AWS S3, this error occurs only when the bucket is created or deleted. For US East 1 , it will not give any redirection as it is the default AWS Region . For any other region , it will give you redirection as it goes first to the default end point , then subsequently it will re-directed to correct end point . Onbar log : 2018-07-28 00:10:27.787685 5792 5790 /opt/IBM/informix/12.10/bin/onbar_d -b -L 0 -w 2018-07-28 00:10:28.060402 5792 5790 Using IBM's PSM version 12.10.FC12 as the Storage Manager. XBSA API version is 1.0.3. 2018-07-28 00:10:28.261216 5792 5790 Archive started on rootdbs (Requested Level 0). 2018-07-28 00:10:28.403077 5792 5790 Begin level 0 backup rootdbs. 2018-07-28 00:10:28.403710 5792 5790 Starting Filter /usr/bin/gzip -c. 2018-07-28 00:10:28.412312 5795 5792 Successfully connected to Storage Manager. 2018-07-28 00:10:30.848897 5795 5792 XBSA Error: (BSAEndData) A system error occurred. Aborting XBSA session. 2018-07-28 00:10:30.850106* 5795 5792 ASSERT: file bar_unix.c line 1325 - contact product support 2018-07-28 00:10:30.850106* 5795 5792 See also: /opt/IBM/informix/12.10/tmp/core 2018-07-28 00:15:31.035592 5792 5790 XBSA Error: (BSAInit) A system error occurred. Aborting XBSA session. 2018-07-28 00:20:31.219425 5792 5790 XBSA Error: (BSAInit) A system error occurred. Aborting XBSA session. 2018-07-28 00:25:41.404369 5792 5790 XBSA Error: (BSAInit) A system error occurred. Aborting XBSA session. 2018-07-28 00:25:41.420402 5792 5790 ASSERT: file bar_ins.ec:bar_ins_ins() line 216 - contact product support 2018-07-28 00:25:41.420440 5792 5790 See also: /opt/IBM/informix/12.10/tmp/core Onbar should not crash and print this error message "307 : temporary redirection of endpoint" before exiting | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC14 and 14.10.xC2. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to Informix Server 12.10.xC14 or 14.10.xC2. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC14 and 14.10.xC2. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to Informix Server 12.10.xC14 or 14.10.xC2. * **************************************************************** | |
Comment | |
Fixed in Informix Server 12.10.xC14 and 14.10.xC2. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 17.02.2020 04.03.2020 06.03.2020 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC14, 14.10.xC2 | |