Informix - Problem description

Problem IT32024 Status: Closed

QUERY TAKES LONGER TIME AND OPTIMIZER CHOOSES SEQUENTIAL SCAN INSTEAD OF
INDEX PATH AFTER RUNNING UPDATE STATISTICS MEDIUM/HIGH.

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
After upgrading from 12.10.FC10 to 12.10.FC13 query is doing
sequential scan and taking longer ( 50 sec to 1 min) after
running update statistics high/medium.


Using index directive query runs in 15-18 secs.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available).      *
****************************************************************
Local Fix:
A possible workaround may be to set the onconfig parameter
OPT_SEEK_FACTOR = 0 or 1.

OPT_SEEK_FACTOR is set to favor hash joins on 12.10, and the
default value is 6 which could be too high in some cases.

onmode -wf OPT_SEEK_FACTOR=0
or
onmode -wf OPT_SEEK_FACTOR=1
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available).      *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
27.02.2020
10.12.2020
10.12.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download