Problem IT32428 Status: Closed

INCORRECT NUMBER OF CSM VPS STARTED WHEN USING CSM NETWORK ENCRYPTION

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
In 11.70, when you have 3 cpu vps configured.  If you have a
server configured to use csm network encryption, so ENCCSM, the
server would start 3 csm vps.  This matches the following
documentation:

The communications support module (CSM) class of virtual
processors performs communications support service and
communications support module functions.

The database server starts the same number of CSM virtual
processors as the number of CPU virtual processors that it
starts, unless the communications support module is set to
GSSCSM to support single sign-on. When the communications
support module is GSSCSM, the database server starts only one
CSM virtual processor.

However, in 12.10, the server seems to only be starting 1 csm vp
when using ENCCSM.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC4.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC4.                                                   *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC4.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 (when available) or    *
* 14.10.xC4.                                                   *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC4.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
02.04.2020
17.12.2020
17.12.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download